Serviceline
Serviceline Industrial Sensors
Serviceline Explosion Protection

솔레노이드 드라이버


Narrow down search result list

제품 선정 결과: 8 제품정보

Function

Input

Power Supply

Output

Special


Choose your product


제품정보

1-channel isolated barrier, 24 V DC supply (loop powered), Output 45 mA at 12 V DC, Up to SIL3 acc. to IEC 61508pa

2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 40 mA at 12 V DC, 55 mA current limit, Contact or logic control input, Entity parameter Io/Isc = 110 mA, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508 (bus powered), Up to SIL3 acc. to IEC 61508 (loop powered)pa
1-channel isolated barrier, 24 V DC supply (bus powered), Analog input, digital input,
analog output, digital output, No configuration required, device is self-adapting, HART transparency, Low power dissipation, 3-way isolation, Up to SIL 2 acc. to IEC 61508 in preparationpa
1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 40 mA at 12 V DC, 55 mA current limit, Contact or logic control input, Entity parameter Io/Isc = 110 mA, Line fault detection (LFD), Test pulse immunity, Up to SIL 2 acc. to IEC 61508 (bus powered), Up to SIL3 acc. to IEC 61508 (loop powered)pa
1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 40 mA at 11.2 V DC, 55 mA current limit, Contact or logic control input, Entity parameter Io/Isc = 93 mA, Line fault detection (LFD), Test pulse immunity, Up to SIL 2 acc. to IEC 61508 (bus powered), Up to SIL3 acc. to IEC 61508 (loop powered)pa
2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 40 mA at 11.2 V DC, 55 mA current limit, Contact or logic control input, Entity parameter Io/Isc = 93 mA, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508 (bus powered), Up to SIL3 acc. to IEC 61508 (loop powered)pa
1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 60 mA at 13 V DC, 65 mA current limit, Gas group IIB, Contact or logic control input, Line fault detection (LFD) with separate output, Up to SIL 2 acc. to IEC 61508 (bus powered), Up to SIL3 acc. to IEC 61508 (loop powered)pa
1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 12 V DC, Line fault transparency (LFT), Test pulse immunity, Up to SIL3 acc. to IEC 61508pa
Download the compendium on Functional Safety

Free PDF Download: Compendium Functional Safety

Download our free PDF compendium on Functional Safety and learn more about the specific standards and methods of risk reduction. We also show you how to implement safety equipment and provide you with a helpful glossary for your daily work.